Skip to main content
← Industrial SCADA overview

Captured from the application

The right screen.
For each workflow.

Actual screens from the running IFSN application, captured on 31 October 2026. Browse by protocol or subject, then open an image at full size to inspect its details.

These are recorded screenshots, not an embedded live plant connection. Original simulator, unavailable, stale and diagnostic-quality indications are retained. Availability depends on the installed release and commissioned configuration.

Protocol workspaces

Each image is taken from its named protocol workspace. A configured interface, simulator value or GOOD badge alone does not establish physical-device compatibility.

IFSN Modbus TCP live-value table with raw readings and quality
Modbus TCP — live values, raw readings and original GOOD/UNKNOWN quality states.Open original · 1059 × 438
IFSN Modbus RTU serial-device setup workspace
Modbus RTU — serial-device configuration workspace from the running application. This screenshot demonstrates the interface, not a commissioned RTU connection.Open original · 530 × 540
IFSN IEC 61850 MMS live values and source-quality states
IEC 61850 MMS — Live Values cards show source references and original GOOD/COMMUNICATION_ERROR states.Open original · 1600 × 1050
IFSN Sampled Values waveform workspace and reception diagnostics
Sampled Values — native-resolution waveform workspace. This capture reports stale input; reception and synchronization warnings are retained.Open original · 1600 × 1100
IFSN CAN and CAN FD decoded-signal and adapter workspace
CAN / CAN FD — decoded signals, adapter configuration and signal mapping from the running session. Physical compatibility depends on the selected interface.Open original · 1600 × 1050
IFSN PROFIBUS simulator and gateway workspace
PROFIBUS — the session explicitly uses Simulator mode. Physical integration requires compatible interface hardware or a gateway.Open original · 1600 × 993
IFSN connected Zigbee USB coordinator commissioning and status panel
Zigbee — connected USB coordinator status and serial-interface controls. Device network identifiers are excluded from the capture.Open original · 1600 × 321
IFSN MQTT and HTTP input-value table with protocol and quality columns
MQTT / HTTP input — actual shared input table showing protocol-labelled values and quality. Acquisition provenance depends on the configured source.Open original · 1059 × 362
IFSN Wi-Fi HTTP input values and quality table
Wi-Fi / HTTP inputs — the shared input-value table from the Wi-Fi Devices workspace. Connection settings and endpoint addresses are outside the capture.Open original · 1059 × 362

Dashboards & electrical diagrams

Existing saved views and an imported drawing, captured without changing their configuration.

IFSN saved Modbus dashboard with configured widgets and live quality states
Live Dashboard — the existing saved Modbus Dashboard, captured without adding or changing widgets. Original quality states remain visible.Open original · 1600 × 1000
IFSN electrical bay overview with single-line diagram and measurements
Electrical bay — BAY1 overview, single-line diagram and source-quality-labelled measurements from the running application.Open original · 1600 × 1050
IFSN Overall SLD displaying an imported medium-voltage drawing in read-only runtime mode
Overall SLD — imported DXF drawing in Runtime, read-only monitoring mode. The session shows one live binding and unconfigured ratings.Open original · 1600 × 1100
IFSN common tag database showing protocol, device, value, quality and source time
Common tags — shared tag database with protocol, values, quality and timestamps. Simulator and physical-source identities remain as displayed.Open original · 1600 × 740

History, alarms & energy

The application's recorded trends, configured alarms and bay energy-reporting interface.

IFSN historian trend chart with tag and time-range controls
Historian / Trends — selected CAN tag and one-hour historical interval. Source provenance is determined by the configured acquisition, not by the chart.Open original · 1600 × 688
IFSN active alarms and recent alarm history
Alarms — configured rules and recent alarm history from the running application, with original state labels retained.Open original · 1600 × 1000
IFSN bay energy and billing view with consumption cards and energy trend
Energy & Billing — actual BAY1 consumption and trend view. The captured interval contains zero totals; this is not revenue-meter certification.Open original · 1600 × 1050

Disturbance records

Registered records and an existing COMTRADE waveform. Recorded disturbance files are distinct from current live data.

IFSN COMTRADE collection showing registered complete disturbance records
COMTRADE Collection — loaded record list with 23 registered records and complete CFG/DAT pairs. FTP endpoint settings are outside the capture.Open original · 1600 × 1050
IFSN COMTRADE viewer displaying waveforms from an existing registered disturbance record
COMTRADE Viewer — waveforms from registered record 012F0004. This is a recorded disturbance, not the current live stream.Open original · 1287 × 601

Power Quality Analyzer

Overview, harmonics and waveform workspaces from the same analyzer. Original quality, stale-input and synchronization indicators remain visible.

IFSN Power Quality Analyzer overview with original diagnostic-quality warnings
Power quality overview — native-resolution analyzer screen. Current input is STALE; unavailable measurements and original warnings remain visible.Open original · 1600 × 1094
IFSN harmonic analysis with diagnostic-quality warnings
Harmonics — native-resolution spectrum workspace. Current input is STALE; no fresh spectrum is presented as valid.Open original · 1600 × 880
IFSN voltage and current waveforms with phasor analysis
Waveforms & phasors — native-resolution analyzer workspace. Current input is STALE and unavailable chart states are retained.Open original · 1600 × 1098

Sensors, logic & integration

Environmental monitoring, existing smart-plug status, the FBD editor and separate read-only output selection.

IFSN temperature monitoring card and recorded trend with source quality
Temperature monitoring — native-resolution measurement and history view. The current quality indicator is retained; device identifiers are outside the capture.Open original · 1600 × 732
IFSN air-quality and dew-point monitoring panels with unavailable readings
Air quality & dew point — temperature, humidity, PM2.5, VOC and derived monitoring panels. This session reports UNKNOWN/DATA UNAVAILABLE values.Open original · 1600 × 850
IFSN smart-plug status showing AUTO input and hysteresis thresholds
Smart Plug — existing AUTO status, shared temperature input and hysteresis settings. No selector, setpoint or device command was changed for capture.Open original · 1600 × 708
IFSN FBD editor with block library and selected logic canvas
PLC Logic — selected logic workspace and block library. The displayed canvas has no blocks; no program was created, modified or started.Open original · 1600 × 1050
IFSN OPC UA and MQTT tag-selection workspace
OPC UA / MQTT outputs — tag selection and destination controls. Both output services are disabled in the captured session; no credentials are shown.Open original · 1600 × 1050